PDA

View Full Version : GE dryewr motor wiring



Boman
11-12-2014, 06:49 PM
Model - DDE5100SBLWW

Can't find a schematic showing the wiring on the motor for this dryer. I got them all but the Black and the Lavender.

The wires for this model are on the right side of the motor looking down on it. I want to say the Black went to the top terminal. I do not want to be wrong.

Help!?

Looks like the last motor in this link, except what looks like it might be the brown wire is a double brown on this one.

http://www.applianceaid.com/ge-dryer-motor-replacement.php

Other than that, the colors look the same.
My colors are from the bottom uo - GR, Bu, Y/Bk, BRBR, then the black and the lavender

thefixer
11-12-2014, 10:37 PM
Motor terminal 1 is black, terminal 2 is violet but it doesn't really matter, they can go either way. This is just the switch to complete the heat circuit.

Boman
11-12-2014, 11:06 PM
Appreciate that. Terminal 1 is next to the top, right? Top is 2?

Violet? Dang, I seem to have a hard time remembering that color.
One of them things where you knowsomething does not seem right, bu tyou use it (lavender) anyway.

Thanks again

jeff1
11-13-2014, 01:38 AM
Hi all,


Can't find a schematic showing the wiring on the motor for this dryer. I got them all but the Black and the Lavender.

Attached is the closest that I had.

jeff.

Boman
11-13-2014, 11:57 AM
Thanks , Jeff.
On these inline terminal switches, are they numbered from 1 -6 from top to bottom or bottom to top consecutively, or are 1 and 2 turned around?

Another thing, the numbers on the square switches and the inline switches work the same, right? Can the inlines be changed?

Update on this dryer: I went ahead and put power to it. It runs and heats, but it seems to have a little hum to it. I may put another bas motor on it. That or I set the clamp at the blower housing too far back. I set it all the way back to the motor. The reason I did this was it did not seem to be enough shaft to put the blower wheel on straight.

I trhink I will loosen that and the blower wheel now that I have the whole thing in and let it adjust itself. Maybe it will pull things back out and show the black rubber between the motor and the clamp at the blower housing like in the next to the last picture on that link to the motors.

jeff1
11-13-2014, 12:35 PM
Can the inlines be changed?

You mean the built in motor switch?, if yes, no it cannot be changed.


That or I set the clamp at the blower housing too far back. I set it all the way back to the motor

That should be good....loose and it may travel forward and hit the housing.


are they numbered from 1 -6 from top to bottom or bottom to top consecutively, or are 1 and 2 turned around?


If I have read this correctly, no the numbers don't normally go in order. Heat switch wires ( often #1 and 2 ) can be revered as they are just an open or closed switch for the heat and don't do anything for the motor running.

jeff.

Boman
11-13-2014, 12:39 PM
So, 1 and 2 are not always for the heat circuit.

Thanks

jeff1
11-14-2014, 01:46 AM
Most ( all? ) are today, some older ones like Westinghouse used different # terminals for the heat switch.

912

jeff.