View Full Version : Frigidaire LGHC2342LFO not cooling
ponyrider127
01-13-2013, 07:41 PM
Today the unit stopped cooling. Both fans are working and compressor is cold to the touch, Clean coils, no ice build up.
Any idea's where to start looking?
jeff1
01-13-2013, 08:55 PM
Hi,
LGHC2342LFO
Lat digit will be an 0 ( zero ).
Both fans are working and compressor is cold to the touch, Clean coils, no ice build up.
Any idea's where to start looking?
Power to the compressor, no power to the compressor tested with a volt meter....gotta see why is it cool and not running. Power to the compressor and no go = compressor or start relay/over load issue. No power and a control/board is likely the issue.
No pic.
Switch board Manufacturer Number 5303918562 (http://www.repairclinic.com/referral.asp?R=153&N=1865445)
#50 is the control board.
136
jeff.
ponyrider127
01-13-2013, 10:02 PM
Hi,
Lat digit will be an 0 ( zero ).
Power to the compressor, no power to the compressor tested with a volt meter....gotta see why is it cool and not running. Power to the compressor and no go = compressor or start relay/over load issue. No power and a control/board is likely the issue.
No pic.
Switch board Manufacturer Number 5303918562 (http://www.repairclinic.com/referral.asp?R=153&N=1865445)
#50 is the control board.
136
jeff.
Thanks Jeff for your reply,
I do have power to the inverter on the compressor. I checked the red and black double plug both sides. Black=124v, Red=106v and one purple=124v.
jeff1
01-14-2013, 01:31 AM
I do have power to the inverter on the compressor
I usually carry a used/good inverter to try as that is as far as testing will get us.....more often the compressor kills the inverter and we replace the compressor and inverter together.
The inverter can be tried first as this company will refund the part cost if it does not work.
137
Inverter board, compressor Manufacturer Number 241577505 (http://www.repairclinic.com/referral.asp?R=153&N=1512577)
138
Compressor kit Manufacturer Number 5304475104 (http://www.repairclinic.com/referral.asp?R=153&N=1554610)
jeff.
ponyrider127
01-14-2013, 01:53 AM
I usually carry a used/good inverter to try as that is as far as testing will get us.....more often the compressor kills the inverter and we replace the compressor and inverter together.
The inverter can be tried first as this company will refund the part cost if it does not work.
137
Inverter board, compressor Manufacturer Number 241577505 (http://www.repairclinic.com/referral.asp?R=153&N=1512577)
138
Compressor kit Manufacturer Number 5304475104 (http://www.repairclinic.com/referral.asp?R=153&N=1554610)
jeff.
Thats not good news considering it is not 2 years old.
jeff1
01-14-2013, 02:01 AM
Nope, never good news! :(
Check the warranty!
jeff.
ponyrider127
01-15-2013, 01:07 PM
I ordered the inverter today after my wife told me about the power surges (On & off) that happened Thursday nite. We had about 6 in about 1 min. I think that is what took out the inverter. The inverter is off and I could test the power coming out of the inverter which showed no power coming out to the compressor. When I put the new part on I will post the results.
Thanks for all of your help. :cool:
jeff1
01-15-2013, 04:05 PM
When I put the new part on I will post the results.
Great :)
jeff.
ponyrider127
01-17-2013, 06:21 PM
Jeff,
Replaced the new part and I still do not have any power to the plug for the compressor. I do have 124v power going into the converter on the purple, and black but only 105v on the red. Should all be 124v? What is the voltage on the plug for the compressor suppose to be coming out?
I think I found out that the current to the compressor is DC not AC. If this is the case the compressor is shot.:mad:
jeff1
01-18-2013, 12:59 AM
149 pic has input and output
I couldn't find much more...yes power is converted.
jeff.