View Full Version : Maytag MAV7600AWW - No Cold Water
twerth
04-07-2013, 01:10 PM
My washer will put out hot and warm water, but no cold. I only get warm water on the cold settings.
I'm thinking I've got a bad temperature control board, but wanted to get opinions before I start spending money on parts. Thanks in advance.
jeff1
04-07-2013, 01:50 PM
Hi,
I usually try a test cord directly on the cold 1/2 of the fill valve and plug the test cord directly into the wall outlet to make sure the cold 1/2 of the fill valve is ok.
If it is, yes you are correct the ATC board is normally toast then.
238 Analog water temperature control board (http://www.repairclinic.com/referral.asp?R=153&N=940172)
jeff.
twerth
04-07-2013, 02:43 PM
I'd thought of that, but if the cold water valve wasn't working I wouldn't have warm water, right?
jeff1
04-07-2013, 05:59 PM
Yes it should be working...but normally don't presumme to make sure...just in case.
jeff.